FIRECRUNCH K-ROOF

PASSSIVE FIRE BOARD Tongue & Groove TG19mm

FireCrunch K-Roof is a tongue and groove TG19mm sheeting for the purpose of preventing bushfire entry though the steel or tiled roof which will otherwise warp and peel off in extreme heat, being mainly only 0.48mm thick metal.

K-Roof underlay goes over the roof trusses under the steel roofing and meets BAL FZ and will prevent fire entry through the roofing and contributes to the overall sealed “Fire Box” principle designs of FCA which prevent external and internal ignition.

NATA LABS CSIRO TEST MogO NSW

FCA K ROOF FCA 2 TG 19HD SMOOTH UPPER FACE sanded face

K-Roof 2TG 19HD Smooth Upper Face/Sanded Face

QUICK REFERENCE TOPICS

  • (ATL) Accredited Testing Laboratory -NATA.

  • Fire resistant to extremely high temperatures (1200ºC).

  • Meets AS 3959 BAL FZ and more, up to FRL 90/90/90.

  • Non-combustible (AS 1530.1) valid 2029 (ATL) NATA CSIRO.

  • NCC 2022 C1 TO C19 AS1530.4 2014 – NCC 2022.

  • NCC C2.2, C2.6, CLD9, C2D11 and others under NCC 2022 Fire Hazards.

  • Smoke and heat release AS3837 NATA CSIRO (ATL).

  • 30, 60, 90 and 120 minute fire resistance in load and non-load bearing tests.

  • Timber and steel fire tested (AS1530.4-2014) valid 2029 NATA CSIRO (ATL).

  • AS5367 Resistance to Incipient Spread of Fire/Flashover.

  • Non-asbestos, AS4964 (ACL) NATA Labs Australian Certification.

  • Resistant to flooding and prolonged water emersion.

  • Resistant to bacteria moisture, humidity, mould and mildew.

  • Completely resistant to termites and insects.

  • Low thermal conductivity ~0.44 (W/mk).

  • Higher R-values than plasterboard.

  • Less expensive, eliminates multiple layers of plasterboard for high FRL.

  • (RISF) Resistance to Incipient Spread of Fire and Flashover (AS5637 CSIRO) ATL.

  • Lowest CO2 pollutive 5% vs. plasterboard 95%.

AUSTRALIAN STANDARDS (CERTIFICATED IN AUSTRALIA NATA LABS CSIRO)

See Certifications

Fire
FRL 90/90/90 1 x 10mm sheet EACH SIDE STEEL FRAMES FRL 60/60/60 1 x 10mm sheet PER SIDE TIMBER FRAMES

Impact
10 times stronger than plasterboard.
LOAD BEARING 55kN (1.5 hrs) at 1000⁰C (see CSIRO fire test report).

Acoustics
Rw 62 AS 717.1 (See Certifications)

Asbestos
Nil content test AS 4964 Nil Chloride
R and U value (See Certifications).

Handling
Cuts, saws, drills, routs, with timber tools, power gun screwing, massive time saving on installation.

Labour Cost Benefits
FireCrunch requires 1 sheet each side for FRL up to FRL 90/90/90 (FyrChek needs 3 layers 13mm each side) or 2 layers 16mm.

Strength
10 x Stronger than plasterboard density 1.15g/cm3.

Eco-Friendly
95% less CO2 emission than plasterboard